Perforations are not through – Case #181

February 26, 2014

by

“A picture is worth a thousand words”. Practical solutions to problems encountered in the manufacturing process that demonstrate how we assist our customers’ factories to produce Right from the Start TM.

Problem: perforations are not through and uniform.

case 181 pic 1 impactiva footwear qa case 181 pic 2 impactiva footwear qa case 181 pic 3 impactiva footwear qa case 181 pic 4 impactiva footwear qa

Impactiva solution: we got the factory to repair and clean the perforation punches in the dies. We educated the cut component QC people to check the perforations after cutting. And we suggested them to clean the perforation punches periodically, for example, once in a shift.

case 181 pic 5 impactiva footwear qa case 181 pic 6 impactiva footwear qa case 181 pic 7 impactiva footwear qa case 181 pic 8 impactiva footwear qa

Stay tuned for more Impactiva technical solutions to every day production problems.